Home > Catalog > Physiology
Product
Category
iWorx 100B Data Acquisition System
iWorx 100B Data Acquisition System
Show images gallery
Single channel recorder providing a cost-effective, high performance solution for dedicated applications such as Langendorff or working heart preps where only one biopotential recording channel is required

- More information - - Contact Bioseb -
Technical specifications
Other products / accessory  

Quick Request
This page is available in following languages:
The iWorx 100B Data Acquisition System is a single channel recorder that provides a cost-effective, high performance solution for dedicated applications such as Langendorff or working heart preps where only one biopotential recording channel is required.

The iWorx 100B has one isolated input channel and is equipped with a low voltage stimulator and an audio output. This recorder delivers the high resolution/low noise performance required for small animal cardiovascular research, Oocyte clamp nerve recording.

Resolution and Noise
The iWorx 100B uses a 16-bit A/D converter to sample data over its full input range of ±1V at speeds up to 200 kHz. Its low noise greatly reduces the need for gain and offset.

Versatile Bioamplifier
The iWorx 100B offers a wide selection of low pass and high pass filters* and is safe for human connection.
*IX-100B high pass filter values (MHz): 0.03, 0.3, 3, 30, 100
*IX-100B low pass filter values (MHz): 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2000, 3000, 4000, 5000, 6000, 7000, 8000, 9000, 10000, 20000

Input Range
±1V, ±250mV, ±125mV, ±50mV, ±25mV, ±12.5mV, ±5mV, ±2.5mV

Low Voltage Stimulator
The iWorx 100B has a software programmable 16 bit, +/-5V stimulator (DAC). Parameters for stimulator, such as pulse width, frequency and amplitude, may be changed “on-the-fly” using handy controls located in the LabScribe2™ software tool bar. Standard protocols include Pulse, Train, Step, Triangle and Ramp. In applications involving isolated heart, the stimulator may be programmed for pacing.

Software
The iWorx 100B recorder is controlled by LabScribe2 software, a powerful recording and analysis software package. LabScribe2 has an intuitive, user-friendly interface for setting up acquisition screens, calibrating signals and analyzing data. Up to 128 channels of data can be displayed simultaneously at sampling rates as high as 100,000 samples/second.

A comprehensive set of analysis routines have been pre-configured making data analysis and interpretation quick and easy. Specific analysis modules for cardiovascular research are available to analyze pressure signals, blood flow data, ECG recordings, ventricular pressure-volume loops and sonomicrometry dimension data.

ECG Option:

This system includes the IX-100B single channel biopotential amplifier and recorder.

This configuration is a cost-effective solution for those only interested in measuring a single lead of ECG and no other physiological signals simultaneously.

The gain, high-pass filter setting and low-pass filter setting are configured via software.

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

No. of Biopotential Channels 1
Input Range Software Configurable
Resolution 16 Bit
Sampling Speed 200 kHz
High Pass Filters Software Configurable
Low Pass Filters Software Configurable
Isolation 3 kV
Connector IEC-60601-1 Touch Proof
Power 5 VDC 2.6A
Enclosure Plastic
Interface USB
Enclosure Plastic
Warranty 3 years
Software LabScribe2 Recording and Analysis Software

Model:
IX-100B
iWorx 100B Data Acquisition System
Contact us

Linked products:
BIO-IX214
Data acquisition teaching unit
Contact us
BIO-IX118
IWORX Data Acquisition System
Contact us
BIO-ETH256
Two Channels Combinaison Bridge-ECG-EMG-EEG Amplifier
Contact us
BIO-ETH401
Four channel transducer amplifier
Contact us
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our iWorx 100B Data Acquisition System

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521