Home > Catalog > Behaviour
Product
Category
SHUTAVOID software
SHUTAVOID software
Show images gallery
A user-friendly interface to conduct active and passive avoidance procedures in an automated manner

- More information - - Contact Bioseb -
Technical specifications
Other products / accessories  

Quick Request
This page is available in following languages:
SHUTAVOID software is an implemented version of the Bioseb SHUTTLE-8 software offering a user-friendly interface to conduct active and passive avoidance procedures in an automated manner.

The Software SHUTAVOID controls independently up to 8 Shuttle Boxes or Passive Cages. The software detects how many cages are physically present and activates the corresponding windows. The system includes a test mode to enables immediate and reliable checking of the functioning of all the elements of the experimental chamber.

The program controls the presentation of visual and acoustic stimuli and shock duration, at the same time that it records the position of the experimental animal in each compartment of the experimental cage, deciding about stimuli presentation accordingly.

Unlimited number of schedules can be defined and used either by common or different experimental cages. The protocol editor allows the configuration of all the basic parameters necessary to set an active and passive avoidance experiment: habituation period, duration of the inter-trial interval (fixed or randomized), activation and duration of the conditioned stimulus (light, sound or both), activation, latency and duration of the unconditioned stimulus (electrical shock), latency for considering the response as “null”, door status (open/closed), number of trials, cut-off time for response etc…

The program runs automatically when the animal is detected in the cage (independently for each cage). During the acquisition of data, information about the protocol state, animal position and current data can be visualized for each cage on the corresponding control window.

Data related to each of the observed animal responses are stored into result files that pick up the information acquired during the working session. The data files can be open and re-analysed to generate ASCII-coded reports in which the information is summarised for each trial or groups of trials (user-defined).

Parameters Measured
• Number and latency of conditioned responses (active avoidance)
• Number and latency of unconditioned responses (active avoidance)
• Number and latency of null responses (active avoidance)
• Number and latency of responses during intertrial (active avoidance)
• Number of compartment crossing during the inter-trial interval (active avoidance)
• Mean of the responses latencies (active avoidance)
• Latency to enter into the black compartment (passive avoidance)

Key features
• Allows editing protocols for both active and passive avoidance
• Experimental chambers can be controlled independently
• A Test mode enables immediate and reliable box checking
• The program runs automatically when the animal is detected in the cage
• Animal position and current data can be visualized on-line
• ASCII files with recorded data
• Re-analyses data in user-defined intervals of time

Components included
• Software Floppy Disks with protection key
• PCI 7200 card for PC
• Cables, connectors
• Instructions manual
• Free software updates of the acquired system
• Free Technical Assistance
• Free Scientific support

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Computer requirements 1.5 GHz Processor or higher, 256 MB of RAM (512 MB recommended) with PCI 32-bit bus master expansion slot available
System requirements Windows™ 98, 2000 or XP compatible operating system

Model:
SHUTAVOID
SHUTAVOID software
Contact us

Accessories :
LE-60.050
Interface for 2 cages
Contact us
LE-60.400-E
Interface for 4 cages
Contact us
LE-60.800-E
Interface for 8 cages
Contact us
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our SHUTAVOID software

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521
E-Mail :info@bioseb.com