Home > Catalog > Physiology
Product
Category
Data acquisition teaching unit
Data acquisition teaching unit
Show images gallery
The From now On POPULAR IX 214 Unit is the perfect rugged, reliable, four-channel data recording unit, engineered to take years of classroom use and abuse !

- More information - - Documents - - Contact Bioseb -
Users
Technical specifications
Other products / accessories  
  • INSERM Faculté de médecine Lille, France
  • ESCPI Paris, France
  • Ecole Nationale Vétérinaire Alfort, France
  • Faculté des sciences d'Orléans Orleans, France
  • Service de santé des armées Grenoble, France
  • Faculté des sciences de Toulouse Toulouse, France
Download PDF
Quick Request
This page is available in following languages:
Presentation
The device enclosure is constructed from extruded aluminum, with a minimum of student-accessible controls and adjustments. With simply one mouse click, the unit can be configured for records of EEG, EMG (EOG) or ECG.

In exclusivity, the iWorx 214 includes a dual-channel biopotential amplifier designed for use on human and rodents subjects. Two additional channels accept any sensor you would like to adapt from older or other systems, like pressure, temperature and force sensors, voltage output of pH meters, spectrophotometers and other laboratory devices. The iWorx 214 also includes a stimulator useful for a variety of human and animal labs. The recorder interfaces to the PC via the USB bus, which provides aggregate sampling at 100 kHz continuous, more than fast enough for just about any teaching experiment..

Physiology Teaching Kits
BIOSEB provides Combination Animal/Human Physiology Teaching Kits that include everything you need to conduct a comprehensive lab course in human and animal physiology. All of the packages contain all of the transducers and lab experiments included in the human physiology teaching kits, plus the transducers and documentation for a total of 33 experiments and 123 exercises.
The additional experiments in animal physiology cover metabolism, membrane and action potentials, muscle activity, and ionic and osmotic balance.
With the addition of a high voltage stimulus isolator, the kits support a total of 34 experiments with 127 exercises.
Ones can either configurate its own system by choosing the suitable sensors and sofware configuration. These kits are optimized for the iWorx high speed, high resolution 214 Recorder and supporting accessories.

System Requirements
The iWorx 214 requires a minumum Pentium II-level computer running Windows 98, ME, 2000 or XP with at least 64 megabytes of RAM, and at least 10 megabytes of free space on the hard drive. Internet connection is required for free automatic upgrades.

Key Hardware Features
• All hardware components carry a three-year unconditional warranty.
• Stimulator is built-in to the recording unit.
• Intelligent inputs adjust transducer gain automatically.
• Firmware and software is upgradeable free-of-charge over the web.
• Sampling speeds of 1 to 100 kHz continuous and 1 to 100 kHz snapshot.
• Electronic design meets or exceeds UL safety standards for lab use.

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Analog Inputs 2 isolated differential biopotential and 2 single-ended/differential transducers
Biopotential Amplifier Safe for use on human subjects - includes optically isolated input and AAMI input cable
Input Impedance 10 Gigohms
Amplifier Frequency Response 2 KHz
ADC Resolution 16 Bit
System Noise 1 LSB (< 1 mV)
Sampling Rate Continuous 100,000 samples/second aggregate
Input Range +5 V
Excitation Voltage +5 V differential input only
Analog Output 1 (differential)
Output Range +5 V, 100 V with optional SM-100
Output Current 50 mA
Output Resolution 12 Bit
Trigger 1 (TTL)
Warranty and Upgrades The iWorx 214 hardware is protected by a three-year warranty. Software and firmware upgrades are free, and are automatically delivered to registered users via the Web. LabScribe software may be freely distributed to students.

Model:
BIO-IX214
Data acquisition teaching unit
Contact us

Accessories :
BIO-IXBP100 Intravascular blood pressure transducer
BIO-IXDT475 Displacement transducer
BIO-FT104 Force transducer
BIO-RM 200 Respiration monitoring belt
BIO-PT 100 Pulse plethysmograph
BIO-TM100 Temperature sensor
BIO-SP304 Spirometer
A full range of professional sensors and cables is available on request
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our Data acquisition teaching unit

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521
E-Mail :info@bioseb.com