Home > Catalog > Physiology
Product
Category
Benchtop Ultrasonic Flowmeters
Benchtop Ultrasonic Flowmeters
Show images gallery
Using Benchtop Ultrasonic Flowmeters is the classical method of determining blood flow velocity in experimental preparations. It offers the lightest, smallest transducers of any techqnique available for this measurement.

- More information - - Documents - - Contact Bioseb -
Publications
Technical specifications
Other products / accessory  
  • Giudicelli, J.F., Berdeaux, A., Richer, C. and Thuillez, C., Use of ultrasonic and microsphere techniques to evaluate regional aspects of vasodilators therapy in myocardial ischemia, arterial hypertension and heart failure., Journal of Hypertension 10(5):S29-S36,1992.
  • Giudicelli, J.F., Drieu La Rochelle, C. and Berdeaux, A., Effects of cromakalim and pinacidil on large epicardial and small coronary arteries in conscious dogs., Journal of Pharmacology Exp & Ther 255:836-842,1990.
  • Forrat, R., de Lorgeril, M., Hadour, G., Sebbag, L., Delaye, J., and Ferrera, R., Effect of Chronic Oral Supplementation with alpha-Tocopherol on Myocardial Stunning in the Dog., Journal of Cardiovasc Pharma 29:457-462. 1997.
  • Schulz, R., Post, H., Sakka, S., Wallbridge, D. and Heusch, G., Intraischemic Preconditioning: Increased Tolerance to Sustained Low-Flow Ischemia by a Brief Episode of No-Flow Ischemia Without Intermittent Reperfusion., Circulation Research 76(6):1995.
  • Atar, D., Serebruany, V., Poulton, J., Godard, J., Schneider, A. and Herzog, W.R., Effects of magnesium supplementation in a porcine model of myocardial ischemia and reperfusion., Journal of Cardiovascular Pharmacology 24:603-611,1994.
Download PDF
Quick Request
This page is available in following languages:
The Bioseb-Triton Technology Model 100 Pulsed Doppler Flowmeter Module is a precision instrument designed to measure blood flow velocity in experimental preparations. As a stand-alone instrument it operates individually or in conjunction with other external synchronized instruments. The Pulsed Doppler Flowmeter is a state-of-the-art system for measuring blood flow velocity. The low-mass, inexpensive transducers are ideal for long term, chronic implantation, particularly when compared to the bulky, heavy transducers required for other technologies. These transducers use lightweight, non-shielded PVC-insulated wire.

Blood flow velocity is measured by projecting bursts of high frequency ultrasound diagonally across the blood vessel. Sound is backscattered from blood cells and the frequency of the scattered sound is shifted in proportion to the velocity of the cells. The scattered signal is detected and a voltage proportional to the velocity of the blood flow is developed for recording. A variable range gate control allows the user to measure blood flow velocity at many points across a blood vessel.

This module incorporates a number of unique features not found in other designs:
A patented noise reduction circuit, Dynamic Noise Reduction, improves the signal-to-noise ratio by as much as 10 dB compared to other pulsed Doppler flowmeter designs.
Range information is presented on a front panel LED display in 0.5 mm increments and as a proportional DC voltage at the back panel.
The instantaneous flow velocity and direction sense is displayed on a dynamic LED bar graph display also on the front panel.

The most unique feature of the Model 100 is its internal calibration circuitry. The calibration is a true end-to-end calibration using a family of frequencies developed from the main quartz crystal clock. These stable, accurate frequencies are determined from the Doppler equation, the operating frequency and the transducer geometry. Other commercial pulsed Doppler designs utilize a simple voltage divider across the power supply as a calibration.

The pulsed Doppler Flow Module is available in 20 and 10 MHz versions for use on small and medium blood vessels. Many different implantable transducers are available to suit specific applications.

DNR is a registered trademark of National Semiconductor.

Note: Please have a look at our complete selection of doppler probes for all your most accurate flow measurements: Doppler Flow Cuffs, Special Doppler Flow Transducers... a downloadable catalogue is available for all probes.

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Model 10 MHz (please contact us for 20 MHz model specifications)
Ultrasonic Frequency 10 MHz crystal-controlled
Pulse Repetition Frequency 62.5 KHz
Transmitter Burst 8 cycles
Range Gate 1-12mm
Audio Bandwidth
High Pass and Low Pass Filters
are 4-Pole Butterworth response
200 Hz-15 KHz
200 Hz-75 KHz
200 Hz-3 KHz
Data Filter:
Switch Selectable
Butterworth-Thompson
DC- 5 Hz
DC-25 Hz
DC-50 Hz
Meter Scale (Full Scale)AAA
(cm/sec) 45-degree Transducer
100 (8928 Hz)
50 (4464 Hz)
20 (1786 Hz)

Model:
FLOW100
Benchtop Ultrasonic Flowmeters
Contact us

Linked products:
DYE-TRACK
Fluorescent & non-radioactive microspheres
Contact us
SYS6-CBI
Modular Rack Measurement Instruments
Contact us
TRT-PROBES
Doppler probes
Contact us
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our Benchtop Ultrasonic Flowmeters

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521
E-Mail :info@bioseb.com