Home > Catalog > Physiology
Product
Category
Ultra-Miniature Pressure-Volume Catheter
Ultra-Miniature Pressure-Volume Catheter
Show images gallery
The smallest catheter in the world for simultaneously measuring LV pressure and volume and creating the least possible disruption in small mouse hearts.

- More information - - Documents - - Contact Bioseb -
Technical specifications
Other products / accessories  
Download PDF
Quick Request
This page is available in following languages:
PRESENTATION

The Scisense Pressure-Volume system brings an advanced solution to the problem of characterizing the cardiac phenotype of transgenic mice. Our integrated catheter for simultaneously measuring LV pressure and volume is the smallest such catheter in the world and creates the least possible disruption in small mouse hearts.

Only 1.2 French in size, our P-V catheter is the ultimate in the assessment of hemodynamic parameters and cardiac function, allowing continuous measurement of LV pressure and volume. In addition, our sensors are small enough to slip through aortic bands or the lumens of other devices, and no de-bubbling or flushing is required.

The P-V catheter includes our high fidelity pressure sensor (.39 mm diameter) and four electrode rings (.37 mm diameter, .25 mm width). The similar sizes of these components allow for a smooth catheter tip without any bulges that can otherwise make insertion difficult.

Catheter electrode spacing is available for both mice and rats. For mice, the inner electrode segment length is 4.5 mm (centre to centre). For rats, the inner segment length is 9.0 mm. For both types of catheter the outside electrode rings are spaced 0.5 mm from the inner rings.

All models have the pressure sensor side mounted between the inner electrodes. The associated pressure control box for the catheter contains the signal acquisition and amplification circuitry, providing an analog pressure signal through a standard BNC connection.

FUNCTIONAL PARAMETERS FROM SCISENSE PV SYSTEM:


PRESSURE-VOLUME (PV) CATHETER SPECIFICATIONS:


Scisense pressure-volume catheters are warranted for six months from date of purchase.

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Measurement Range -50 to + 300 mmHg
(temperature range: 32-42°C)
Sensitivity 10µV/V/mmHg or higher
Frequency Response 0 to >10 kHz
Gauge Excitation Constant current
Stability Zero offset drift < 6 mmHg/12 hours
(after 15 minute pre-soak)
Signal Gain Factor 200

Model:
SCI-PV
Ultra-Miniature Pressure-Volume Catheter
Contact us

Linked products:
BIO-IX304
iWorx 300 Series Research Grade Recorders
Four-Channel Data Recorder with 4 differential inputs & LabScribe2 Contact us
SAMBA
Samba - Blood Pressure System
Contact us
SCI-UMPC
Ultra-Miniature Pressure Catheter
Contact us
IX-404-PVL
Data Recorder with Pressure-Volume Loop Analysis
Contact us
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our Ultra-Miniature Pressure-Volume Catheter

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521
E-Mail :info@bioseb.com