Home > Catalog > Physiology
Product
Category
Data Recorder with Pressure-Volume Loop Analysis
Data Recorder with Pressure-Volume Loop Analysis
Show images gallery
An economical, general purpose data acquisition and analysis module for use with any analog amplifier

- More information - - Documents - - Contact Bioseb -
Technical specifications
Other products / accessory  
Download PDF
Quick Request
This page is available in following languages:
Presentation

iWorx 404 is an economical, general purpose data acquisition and analysis module for use with any analog amplifier. The recorder offers 16-bit data collection at speeds up to 10 KHz, providing acquisition speeds appropriate for most research applications. The included iWorx PVLOOP software allows “one-click” control of the entire acquisition process, plus a large library of standard analytical functions to process data. The iWorx 404 recorder is powered via a USB interface to any Macintosh or PC, eliminating the need to install special interface cards. Users are typically recording and analyzing signals within minutes of installation.

Resolution

The iWorx 404 recorder uses a 16-bit A/D converter to sample data over its full input range of ±10V at speeds up to 10kHz. The low noise (<1mV) greatly reduces the need for gain and offset. When used with a standard x10 oscilloscope probe, ranges of ±100V can be monitored.

iWorx PVLOOP Software

The iWorx PVLOOP Software (ref. IX-404-PLV) provides powerful analysis tools. Built-in iWorx PVLOOP acquisition and analysis software is easy and straightforward. It supports real units and a time based display that is not coupled to sample rate. The display can be configured to allow viewing of as many data points as the user desires. Scrolling, zoom-in and zoom-out tools, together with a searchable list of user interventions, make finding important areas of data easy.

iWorx PVLOOP provides a powerful array of built-in data analysis tools. It strikes a balance between the straightforward, general operations that everyone uses and the vertical, complex routines that only you use. The result is a powerful analytical tool that can go to work on your data right away, or be customized to do very specific and complex analyses.

Exceptional Value

iWorx 404 provides turnkey continuous recording solutions at a fraction of the cost and complexity associated with systems requiring PCI bus plug-in cards. No breakout box is required, as connectors are part of the enclosure. In fact, no other hardware is required to get up and running.

System Requirements

iWorx 404 requires a minimum Pentium II or Celeron level 500MHz computer running Windows 98, ME, 2000 or XP with at least 128 megabytes of RAM, at least 10 megabytes of free space on the hard drive, and 1 free USB port. Internet connection is required for web updates.

Available with Pressure Volume Loop Analysis iWorx 404 is available in two configurations, with (IWX/404-PVL) or without (IWX/404) a pressure volume loop analysis.

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Input
Digital Inputs 4
Input Impedance 1M Ohm
Input Range + 10 VDC
Noise <1 mV (1 part in 20K)
Digital Output
Lines 4
Digital Output Connector BNC
A/D Converter
Sample Speed (samples/second) 10,000 simultaneously
Resolution 16 Bit
Interface USB 1.1 / 2.0 full speed
General
Enclosure Plastic (CE Compliant)
Power USB
Software
Software iWorx PVLOOP
Trigger Modes External Trigger (TTL or Contact Closure), Threshold Trigger from Data, User Trigger
Display Real time, user definable Screen Time independent of Sample Rate, User Definable Units, AutoScale, Full Scale or User Defined Scale

Model:
IX-404-PVL
Data Recorder with Pressure-Volume Loop Analysis
Contact us

Linked products:
SCI-PV
Ultra-Miniature Pressure-Volume Catheter
Contact us
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our Data Recorder with Pressure-Volume Loop Analysis

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521
E-Mail :info@bioseb.com