Built for Automation
• Operates stand-alone or from a computer.
• Infusion and withdrawal. Set a single pumping rate, set a dispensing volume, or program up to 41 pumping phases that change pumping rates, set dispens-ing volumes, insert pauses, control and respond to external signals, sound the buzzer.
• Create expandable and reconfigurable multi-syringe systems by attaching pumps to each other.
General Features:
• Infuses and withdraws
• Accepts small syringes or large syringes, up to 60 cc.
• Dispense continuously at a fixed pump-ing rate as low as 6µl/hr or as high as 1200 ml/hr.
• Change pumping rate and direction while pumping.
• Selectable rate units: µl/hr, µl/mn, ml/hr, ml/mn.
• Dispense a specified volume.
• Dispense according to a pumping program to:
- Pre-program dispense volumes. Each volume can be different.
- Automatically change pumping rates or pumping direction.
• Ramp up or down the pumping rate.
• Timed delays between dispensers.
• Automatically pause the program and wait for the user to continue the dispense.
• Synchronize dispenses with other equipment or pumps to change pumping rates in reaction to a sensor or signals from other pumps.
• Send logic signals to other equipment. Change pumping rates in reaction to a sensor.
• Program the audible alarm to beep at any time to alert the operator.
• Enter the pumping program from the keypad or download it from a computer. Operates stand-alone, from an RS-232 computer port or from the TTL logic interface.
• Total volume pumped separately accumulated for infusion and withdrawal.
Programming Features:
• 41 programmable phases.
• Set event interrupts from external signals to cause automatic jumps to another part of the program.
• Conditional jumps based on external inputs.
Nested loops:
• Repeat a section of the program continuously or a set number of times.
Program editing functions:
• Insert and delete program phases.
• Simplifies program development and updating.
• Allows quick removal or addition of program phases.
• Enter programs from the keypad or from a computer.
• Download or upload pumping programs from or to a computer. Store dispensing programs in a file on your computer, then download them to one or more pumps. Specify in the file to send a different pumping program of each pump in the pump network.
• Automatically change pumping rates.
• Insert timed delays between dispenses.
The multi-syringe pump has all the pro-gramming features of the single syringe pump. There are two options: 6 or 8 syringes.
|