Home > Catalog > Analgesia
Product
Category
Elektronisches Von Frey
Elektronisches Von Frey
Show images gallery
Algesimeter zur schnellen und einfachen Messung der Schmerzschwelle

- More information - - Documents - - Contact Bioseb -
Users
Publications
Technical specifications
Other products / accessory  
  • HCUGE Geneve, Suisse
  • BIOCODEX Compiegne, France
  • ECOLE NATIONALE VETERINAIRE NANTES Nantes, France
  • CHU Tours, France
  • ECOLE NATIONALE VETERINAIRE Toulouse, France
  • DUKE UNIVERSITY MEDICAL CENTER Durham, Etats-Unis
  • UNIVERSITY OF MARYLAND Baltimore MD, Etats-Unis
  • INSERM FACULTE DE MEDECINE Paris & Clermont-Ferrand, France
  • MEDIMMUNE Cambridge, Royaume Unis
  • UNIVERSITY OF WASHINGTON Seattle, Etats-Unis
  • FACULTY MEDICINE OF PORTO Porto, Portugal
  • CHU PELLEGRIN Bordeaux, France
  • UNIL Lausanne, Suisse
  • HOWARD FLOREY INSTITUTE Carlton, Australie
  • TROPHOS SA Marseille, France
  • CNRS Valbonne, France
  • CHU DE NICE Nice, France
  • ABBOTT Louvain la neuve, Belgique
  • UNIVERSTITE PARIS 7 Paris, France
  • ANS BIOTECH St Beauzire, France
  • CENTRE HOSPITALIER ESQUIROL Limoges, France
  • LABORATOIRES PIERRE FABRE CASTRES, France
  • SANOFI AVENTIS Vitry sur Seine, Toulouse, Rueil Malmaison, Bagneux, Paris, Montpellier, France
  • ESCPI Paris, France
  • IGBMC PARC INNOVATION ILLKIRCH, France
  • PORSOLT AND PARTNERS Boulogne, France
  • AND MANY OTHERS SINCE 1999...
  • Redondo Castro E., Udina E., Verdú E., Navarro X. (2011) Longitudinal study of wind-up responses after graded spinal cord injuries in the adult rat. Restorative Neurology and Neuroscience, 29(2):115-126. (Spain)
  • Lorenzini K.I., Besson M., Daali Y., Salomon D., Dayer P., Desmeules J. (2011) A Randomized, Controlle d Trial Validates a Peripheral Supra-Additive Antihyperalgesic Effect of a Paracetamol–Ketorolac Combination. Basic & Clinical Pharmacology & Toxicology, 109(5):357–364. (Switzerland)
  • Udina E., Puigdemasa A., Navarro X. (2011) Passive and active exercise improve regeneration and muscle reinnervation after peripheral nerve injury in the rat. Muscle & Nerve, 43(4):500–509. (Spain)
  • Reali C., Fossat P., Landry M., Russo R., Nagy F. (2011) Intrinsic membrane properties of spinal dorsal horn neurones modulate nociceptive information processing in vivo. The Journal of Physiology, 589(11):2733–2743. (France)
  • Favereaux A., Thoumine O., Bouali-Benazzouz R., Roques V., Papon M.-A., Salam S.A. et al. (2011) Bidirectional integrative regulation of Cav1.2 calcium channel by microRNA miR-103: role in pain. The EMBO Journal, 30:3830-3841. (France)
  • Badia J., Boretius T., Pascual-Font A., Udina E., Stieglitz T., Navarro X. (2011) Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichannel Electrode (TIME) in the Rat Sciatic Nerve. Biomedical Engineering, IEEE Transactions, 58(8):2324-2332. (Spain)
  • Fossat P., Dobremez E., Bouali-Benazzouz R., Favereaux A., Bertrand S., Kilk K. et al. (2010) Knockdown of L Calcium Channel Subtypes: Differential Effects in Neuropathic Pain. The Journal of Neuroscience, 30(3):1073–1085. (France)
  • Verron E., Gauthier O., Janvier P., Le Guen H., Holopherne D, Cavagna R. et al. (2010) Analgesic properties of calcium phosphate apatite loaded with bupivacaine on postoperative pain. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 94B(1):89–96. (France)
  • Asensio-Pinilla E., Jaramilloa J., Navarro X. (2009) Electrical stimulation combined with exercise increase axonal regeneration after peripheral nerve injury. Experimental Neurology, 258-65. (Spain)
  • Casals-Diaz L., Vivo M., Navarro X. (2009) Nociceptive responses & spinal plastic changes of afferent C-fibers in three neuropathic models induced by sciatic nerve injury in the rat. Experimental Neurology, 84-95. (Spain)
  • Thibault K. et al. (2008) Antinociceptive and anti-allodynic effects of oral PL37, a complete inhibitor of enkephalin-catabolizing enzymes, in a rat model of peripheral neuropathic pain induced by vincristine. European Journal Pharmacology, 600(1-3):71-77. (France)
  • Duale C. et al. (2008) Cutaneous Amitriptyline in Human Volunteers: Differential Effects on the Components of Sensory Information. Anesthesiology, 108(4):714-721. (France)
  • Lefaucheur J.P., Drouot X., Menard-Lefaucheur I. & al. (2008)Motor cortex rTMS in chronic neuropathic pain: pain relief is associated with thermal sensory perception improvement. J Neurol Neurosurg Psychiatry, 79:1044-1049. (France)
  • Laalou F.Z., de Vasconcelos A.P., Oberling P. & al. (2008)Involvement of the Basal cholinergic forebrain in the mediation of general (Propofol) anesthesia. Anesthesiology, 108(5):888-896. (France)
  • Vivo M., Puigdemasa A., Casals L., Asenio E. & al. (2008) Immediate electrical stimulation enhance regeneration and reinnervation and modulates spinal plastic changes after sciatic nerve injury and repair. Experimental neurology, 211(1):180-193. (Spain)
  • Girard P., Verniers D., Coppé M.C., Pansart Y. & al. (2008) Nefopam and ketoprofen synergy in rodent models of antinociception. European Journal of Pharmacology, 584(2-3):263-271. (France)
  • Pickering G. et al. (2007) Acetaminophen reinforces descending inhibitory pain pathways. The Journal of Clinical Pharmacology, 84(1):47-51. (France)
  • Chassaing C. et al. (2006) Hyperalgesia induced by cutaneous freeze injury for testing analgesics in healthy volunteers. British Journal of Clinical Pharmacology, 61(4): 389. (France)
  • Benani A. et al. (2003) Up-regulation of fatty acid metabolizing-enzymes mRNA in rat spinal cord during persistent peripheral local inflammation. European Journal Neuroscience, 18: 1904-1914. (France)
See tutorial
Download PDF
Play video

Quick Request
This page is available in following languages:
Der neue elektronische EVF3 Algesimeter ist ein einfaches und schnelles Instrument für die Bestimmung der Schmerzschwelle.

Ein EINZIGER Testvorgang genügt, um die Schmerzschwelle mit grosser Reproduzierbarkeit zu ermitteln. Die Schmerzschwelle kann auf der breiten Rücklichtanzeige direkt abgelesen werden. Im Gegenteil zu klassischen Von-Frey-Haaren ensteht durch Feuchtigkeit oder Temperaturwechsel keine Abweichung der Ergebnisse. Das Instrument ist sowohl für Tierverusche als auch in der klinischen Forschung einsetzbar (die Zulassung für die klinische Praxis wird demnächst erteilt). Die Auflösung der Anzeige beträgt 0.1 Gramm.

Hauptfunktionen: • Breite Rücklichtanzeige mit Angabe der maximalen und laufenden Kraft
• Statistische Berechnungen: Durchschnittswert und Standardabweichung von jedem Subjekt
• Selbstständiges Instrument: interner Speicher für bis zu 100 Messwerten, die mit der optionalen Software zu einem PC übertragen werden können.

Optionen zur Benutzungsoptimierung :
• „Patient-Tasten“ verursacht die Erstarrung der Anzeige bei Überschreitung der Schmerzschwelle (für klinische Forschung)
• RS232-Verbindung zur Datenübertragung zu einem PC
• RSIC Software (für Windows 98, 00, oder XP) zur direkten Einfügung der Messwerte in eine Excel-Arbeitsmappe. Diese Option vermeidet Abschreibungsfehler und ermöglicht eine fortgeschrittene Datenanalyse.


Lieferumfang:
• ISO 9000 Kalibrierschein (jährliche Kalibrierung wird von BIOSEB übernommen)
• EMC-Zulassungschein
• 10 Wegwerfspitzen aus Kunststoff
• 1 Federspitze für Schmerzschwelle zwischen 0 und 10 Gramm
• Pedal zur handfreien Nullstellung beim Versuchsstart
• Transportkoffer

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Messbereich 0-500 Gramm (5 N)
Auflösung 0.1 Gramm
Genauigkeit 0.1 Gramm
Überlastschutz 120 % ohne Sensorschaden
Temperaturausgleich zwischen 0 und 50 °C
Anzeige gut lesbare und breite Rücklichtanzeige
Angabe der maximalen und laufenden Kraft
Aufnahmefähigkeitsbalkendiagramm
Ergebnis Schmerzschwelle = maximale Kraft
Statistische Berechnungen Durchschnittswert und Standardabweichung von jedem Subjekt
Interner Speicher bis zu 100 Messwerten
Stromversorgung Netz 220-240 V (andere Spannung auf Nachfrage)

Model:
BIO-EVF3
Elektronisches Von Frey
Contact us

Accessories :
RSIC
RSIC : direkte RS232 Datenübertragung in MS EXCEL + RS232 Kabel
Contact us
Print version Click to order
Information request

Please fill up this form, and our team will contact you as soon as possible with the requested information about our Elektronisches Von Frey

Your e-mail address:


Type of information requested:


Bioseb

Tél :+33 (0)820 825 523
Fax :+33 (0)820 825 521
E-Mail :info@bioseb.com