INSERM FACULTE DE MEDECINE Paris & Clermont-Ferrand, France
MEDIMMUNE Cambridge, Royaume Unis
UNIVERSITY OF WASHINGTON Seattle, Etats-Unis
FACULTY MEDICINE OF PORTO Porto, Portugal
CHU PELLEGRIN Bordeaux, France
UNIL Lausanne, Suisse
HOWARD FLOREY INSTITUTE Carlton, Australie
TROPHOS SA Marseille, France
CNRS Valbonne, France
CHU DE NICE Nice, France
ABBOTT Louvain la neuve, Belgique
UNIVERSTITE PARIS 7 Paris, France
ANS BIOTECH St Beauzire, France
CENTRE HOSPITALIER ESQUIROL Limoges, France
LABORATOIRES PIERRE FABRE CASTRES, France
SANOFI AVENTIS Vitry sur Seine, Toulouse, Rueil Malmaison, Bagneux, Paris, Montpellier, France
ESCPI Paris, France
IGBMC PARC INNOVATION ILLKIRCH, France
PORSOLT AND PARTNERS Boulogne, France
AND MANY OTHERS SINCE 1999...
Redondo Castro E., Udina E., Verdú E., Navarro X. (2011) Longitudinal study of wind-up responses after graded spinal cord injuries in the adult rat. Restorative Neurology and Neuroscience, 29(2):115-126. (Spain)
Lorenzini K.I., Besson M., Daali Y., Salomon D., Dayer P., Desmeules J. (2011) A Randomized, Controlle d Trial Validates a Peripheral Supra-Additive Antihyperalgesic Effect of a Paracetamol–Ketorolac Combination. Basic & Clinical Pharmacology & Toxicology, 109(5):357–364. (Switzerland)
Udina E., Puigdemasa A., Navarro X. (2011) Passive and active exercise improve regeneration and muscle reinnervation after peripheral nerve injury in the rat. Muscle & Nerve, 43(4):500–509. (Spain)
Reali C., Fossat P., Landry M., Russo R., Nagy F. (2011) Intrinsic membrane properties of spinal dorsal horn neurones modulate nociceptive information processing in vivo. The Journal of Physiology, 589(11):2733–2743. (France)
Favereaux A., Thoumine O., Bouali-Benazzouz R., Roques V., Papon M.-A., Salam S.A. et al. (2011) Bidirectional integrative regulation of Cav1.2 calcium channel by microRNA miR-103: role in pain. The EMBO Journal, 30:3830-3841. (France)
Badia J., Boretius T., Pascual-Font A., Udina E., Stieglitz T., Navarro X. (2011) Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichannel Electrode (TIME) in the Rat Sciatic Nerve. Biomedical Engineering, IEEE Transactions, 58(8):2324-2332. (Spain)
Fossat P., Dobremez E., Bouali-Benazzouz R., Favereaux A., Bertrand S., Kilk K. et al. (2010) Knockdown of L Calcium Channel Subtypes: Differential Effects in Neuropathic Pain. The Journal of Neuroscience, 30(3):1073–1085. (France)
Verron E., Gauthier O., Janvier P., Le Guen H., Holopherne D, Cavagna R. et al. (2010) Analgesic properties of calcium phosphate apatite loaded with bupivacaine on postoperative pain. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 94B(1):89–96. (France)
Asensio-Pinilla E., Jaramilloa J., Navarro X. (2009) Electrical stimulation combined with exercise increase axonal regeneration after peripheral nerve injury. Experimental Neurology, 258-65. (Spain)
Casals-Diaz L., Vivo M., Navarro X. (2009) Nociceptive responses & spinal plastic changes of afferent C-fibers in three neuropathic models induced by sciatic nerve injury in the rat. Experimental Neurology, 84-95. (Spain)
Thibault K. et al. (2008) Antinociceptive and anti-allodynic effects of oral PL37, a complete inhibitor of enkephalin-catabolizing enzymes, in a rat model of peripheral neuropathic pain induced by vincristine. European Journal Pharmacology, 600(1-3):71-77. (France)
Duale C. et al. (2008) Cutaneous Amitriptyline in Human Volunteers: Differential Effects on the Components of Sensory Information. Anesthesiology, 108(4):714-721. (France)
Lefaucheur J.P., Drouot X., Menard-Lefaucheur I. & al. (2008)Motor cortex rTMS in chronic neuropathic pain: pain relief is associated with thermal sensory perception improvement. J Neurol Neurosurg Psychiatry, 79:1044-1049. (France)
Laalou F.Z., de Vasconcelos A.P., Oberling P. & al. (2008)Involvement of the Basal cholinergic forebrain in the mediation of general (Propofol) anesthesia. Anesthesiology, 108(5):888-896. (France)
Vivo M., Puigdemasa A., Casals L., Asenio E. & al. (2008) Immediate electrical stimulation enhance regeneration and reinnervation and modulates spinal plastic changes after sciatic nerve injury and repair. Experimental neurology, 211(1):180-193. (Spain)
Girard P., Verniers D., Coppé M.C., Pansart Y. & al. (2008) Nefopam and ketoprofen synergy in rodent models of antinociception. European Journal of Pharmacology, 584(2-3):263-271. (France)
Pickering G. et al. (2007) Acetaminophen reinforces descending inhibitory pain pathways. The Journal of Clinical Pharmacology, 84(1):47-51. (France)
Chassaing C. et al. (2006) Hyperalgesia induced by cutaneous freeze injury for testing analgesics in healthy volunteers. British Journal of Clinical Pharmacology, 61(4): 389. (France)
Benani A. et al. (2003) Up-regulation of fatty acid metabolizing-enzymes mRNA in rat spinal cord during persistent peripheral local inflammation. European Journal Neuroscience, 18: 1904-1914. (France)
Der neue elektronische EVF3 Algesimeter ist ein einfaches und schnelles Instrument für die Bestimmung der Schmerzschwelle.
Ein EINZIGER Testvorgang genügt, um die Schmerzschwelle mit grosser Reproduzierbarkeit zu ermitteln. Die Schmerzschwelle kann auf der breiten Rücklichtanzeige direkt abgelesen werden. Im Gegenteil zu klassischen Von-Frey-Haaren ensteht durch Feuchtigkeit oder Temperaturwechsel keine Abweichung der Ergebnisse. Das Instrument ist sowohl für Tierverusche als auch in der klinischen Forschung einsetzbar (die Zulassung für die klinische Praxis wird demnächst erteilt). Die Auflösung der Anzeige beträgt 0.1 Gramm.
Hauptfunktionen:
• Breite Rücklichtanzeige mit Angabe der maximalen und laufenden Kraft
• Statistische Berechnungen: Durchschnittswert und Standardabweichung von jedem Subjekt
• Selbstständiges Instrument: interner Speicher für bis zu 100 Messwerten, die mit der optionalen Software zu einem PC übertragen werden können.
Optionen zur Benutzungsoptimierung :
• „Patient-Tasten“ verursacht die Erstarrung der Anzeige bei Überschreitung der Schmerzschwelle (für klinische Forschung)
• RS232-Verbindung zur Datenübertragung zu einem PC
• RSIC Software (für Windows 98, 00, oder XP) zur direkten Einfügung der Messwerte in eine Excel-Arbeitsmappe. Diese Option vermeidet Abschreibungsfehler und ermöglicht eine fortgeschrittene Datenanalyse.
Lieferumfang:
• ISO 9000 Kalibrierschein (jährliche Kalibrierung wird von BIOSEB übernommen)
• EMC-Zulassungschein
• 10 Wegwerfspitzen aus Kunststoff
• 1 Federspitze für Schmerzschwelle zwischen 0 und 10 Gramm
• Pedal zur handfreien Nullstellung beim Versuchsstart
• Transportkoffer
THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.
Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.
BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.
Messbereich
0-500 Gramm (5 N)
Auflösung
0.1 Gramm
Genauigkeit
0.1 Gramm
Überlastschutz
120 % ohne Sensorschaden
Temperaturausgleich
zwischen 0 und 50 °C
Anzeige
gut lesbare und breite Rücklichtanzeige Angabe der maximalen und laufenden Kraft Aufnahmefähigkeitsbalkendiagramm
Ergebnis
Schmerzschwelle = maximale Kraft
Statistische Berechnungen
Durchschnittswert und Standardabweichung von jedem Subjekt