BP-2000 BLOOD PRESSURE ANALYSIS SYSTEM
(Model: BP-2000-M-2 - For 2 mice)
The world's leading non-invasive blood pressure analyzer for mice and rats: a state-of-the-art, expandable instrument based on transmission photoplethysmography, highly accurate and reliable for measurements on animals ranging from small mice to extremely large rats. Comes with a powerful, yet intuitive, dedicated software to review and verify your data, and export your results.

- More information - - Contact Bioseb -
Publications
Technical specifications
Other products / accessory  

This page is available in following languages:
! NEW RESEARCH WORK ! A recent publication by Bonnin P, Vilar J, Levy BI in "Life Sci" highlights the merits of using Bioseb's BP-2000 Blood Pressure Analysis System: Effect of normovolemic hematocrit changes on blood pressure and flow

Effect of normovolemic hematocrit changes on blood pressure and flow
Bonnin P, Vilar J, Levy BI
Université Paris-Diderot, Sorbonne-Paris-Cité, Hôpital Lariboisière, 2 rue A. Paré, 75010 Paris, France
Published in "Life Sci" (2016-04-30)


AIMS:

In patients with chronic kidney disease (CKD), severe anemia is associated with increased cardiovascular risk. Although elevating hemoglobin (Hb) and hematocrit (Hct) levels with erythropoiesis-stimulating agents (ESA) improves patients' quality of life, normalization of Hb does not reduce cardiovascular risk and the reason remains unclear.

MAIN METHODS:

We measured the effect of acute isovolumic changes in Hct from 37±5 to 50±2% (mean±SD) on arterial blood pressure (BP), cardiac output (CO), and carotid and renal blood flow (BF), (1) in control rats and (2) after acute blockade of the nitric oxide (NO) pathway by l-NAME.

KEY FINDINGS:

1) In control conditions, BP, CO and carotid and renal BF remained stable for Hct values between 38±2 and 46±1%; 2) for higher Hct values, BP rose together with increasing blood viscosity whereas CO and renal BF decreased; 3) during acute NO blockade, CO, and carotid and renal BF were significantly reduced and remained low whereas BP increased with Hct thus increasing blood viscosity. Our results suggest (1) the ceiling level of endothelium-mediated vasodilation for high values of blood viscosity under control conditions, and (2) the need for efficient endothelial function for vasomotor adaptation of hemodynamic resistances to blood viscosity.

SIGNIFICANCE:

(1) Clinical benefits of ESA in CKD patients with severe endothelial dysfunction are primarily due to increased oxygen transport and supply and, (2) normalization of Hct values in these patients may prove deleterious because of significant increases in BP and reductions in BF associated with high blood viscosity.
BP-2000 Blood Pressure Analysis System - System for 4 mice
System for 4 mice
Presentation

The BP-2000 Blood Pressure Analysis System is the world's leading non-invasive blood pressure analyzer for mice and rats. Its proven technology is now depended on in hundreds of laboratories around the world. More than 500 research papers have been published using the BP-2000.

The BP-2000 Blood Pressure Analysis System was developed for Dr. Oliver Smithies (2007 Nobel Prize in Medicine), to allow him to measure the blood pressure of his groundbreaking transgenic mouse models.

A variety of models for both mice and rats are available to meet every research need.

Operating principle

The BP-2000 uses transmission photoplethysmography, in which variations in the amount of light transmitted through the tail is the basic signal that is analyzed to determine the blood pressure and pulse rate.

Every time the heart beats, a pressure wave travels through the vascular system. When it reaches the tail, the vessels dilate slightly, and thus scatter more red light. (This corresponds to systole.) As the pressure wave passes, the vessels in the tail get smaller as the pressure decreases, and less light is scattered. (This corresponds to diastole.) The variation in light transmitted through the tail is what the BP-2000 displays on the computer screen.

Photoplethysmography is very effective at measuring blood pressure on animals ranging from small mice to extremely large rats. And unlike approaches that use an additional sensing cuff (or volume-pressure cuff), photoplethysmography works more reliably with small mouse tails (and does not require two cuffs on the tail).

The diastolic and systolic pressure can be determined by monitoring the vessel dilation as the occlusion cuffs inflates. Here is a plot of actual data showing where diastolic and systolic are measured:

Simplest Explanation

• Where the waveform amplitude (height) starts to decrease is the diastolic pressure.

• Where the waveform amplitude decreases to and remains at a steady value is the systolic pressure.

More Complicated Explanation

• When the BP-2000 software has determined the pulse rate, it starts inflating the occlusion cuff.

• When the occlusion pressure reaches the diastolic pressure, the amplitude of the waveform starts to decrease, since the vessels cannot dilate as much in response to the heartbeat.

• When the occlusion pressure equals the systolic pressure, the waveform remains at a steady value and thereafter does not decrease, since the vessels cannot dilate at all.


Advantages

• The BP-2000 is the world's most widely used system for non-invasively measuring mouse blood pressure.
• More than 500 research papers have been published using the BP-2000. On average, about one paper a week is published with the BP-2000!
• Highly accurate. The BP-2000 gives results that correlate closely with interarterial measurements (Krege JH, Hodgin JB, Hagaman JR, Smithies O, Hypertension. 1995; 25: 1111-1115).
• Jackson Laboratories, the world's largest supplier of laboratory mice, has a large number of BP-2000 systems that they are currently using for measuring mouse blood pressure.
• Charles River Laboratories, the world's largest supplier of laboratory rats, uses the BP-2000 to establish baseline BP values for their hypertensive rat models. The BP-2000 was featured in their Outlook newsletter from Spring, 2006.

Features

• Measures systolic and diastolic blood pressure, and heart rate. Calculates mean blood pressure.
• Many models for mice and rats. Models are available for two, four, or six mice; and for two or four rats. Combined mouse and rat systems are also available.
• Easily expand your system by adding additional channels (maximum of six for mice, four for rats), or add ability to measure both rats and mice - at a fraction of the cost of buying another system.
• A large range of animals restrainers: 4 sizes for mice, and 6 for rats. Our specially designed restrainers hold the animals comfortably, and allow them to breathe freely.
Automatic temperature control gently warms the animals.
• Works well with both conscious and anesthetized animals.
• Optionally includes a notebook computer. If you provide your own computer, it is easy to download and install the BP-2000 Analysis Software.
Intuitive and powerful software. The BP-2000 Analysis Software displays, measures, and stores blood pressure, heart rate, and waveforms in its built-in database. Your data – including waveforms – can be easily reviewed.
Free lifetime upgrades to the BP-2000 Analysis Software.

Domains of application

• Studies on hypertension
• Vital parameters monitoring during daily lab operations
• Vital parameters monitoring during toxicology studies
• Side effects during drug screening processes
• Research on cardio-vascular pathologies
• Kidney-related diseases
• Metabolic dysfunctions and obesity
• Studies on allergies
• Aging


Publications (Click on an article to show details and read the abstract)


THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Computer requirements Operating system: Windows 7 or higher
Processor: 1.4 GHz recommended (800 MHz minimum)
Memory: 256 MB or higher
USB port: At least one free USB port

Model:
BP-2000-M-2
BP-2000 Blood Pressure Analysis System
For 2 mice Contact us

Related products:
BP-2000-M-6
BP-2000 Blood Pressure Analysis System
For 6 mice Contact us
BP-2000-R-2
BP-2000 Blood Pressure Analysis System
For 2 rats Contact us
BP-2000-R-4
BP-2000 Blood Pressure Analysis System
For 4 rats Contact us
BP-2000-MR-2
BP-2000 Blood Pressure Analysis System
For 2 mice and 2 rats Contact us
BP-2000-MR-4
BP-2000 Blood Pressure Analysis System
For 4 mice and 4 rats Contact us
BP-2000-M6-R4
BP-2000 Blood Pressure Analysis System
For 6 mice and 4 rats Contact us
BP-2000-M-4
BP-2000 Blood Pressure Analysis System
For 4 mice Contact us