The GA-200 is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the sample by volume. This method of expressing the concentration of a gas in a sample is also known as the percent volume fraction. In addition to the sampling and sensing systems in the GA-200, the unit has a fluorescent display used for programming the unit and observing measurements, a keypad for programming the unit’s operation and calibration, and analog outputs that allow the unit to be connected to data recording units like the IX-214.


Operating principle

When measuring the concentrations of oxygen and carbon dioxide in a gas, a sample is pumped from the input port on the front panel of the GA-200, through the sample cell, and out an exhaust port on the back panel of the unit. Gas samples are drawn into the unit through an external filter on the input port that protects the sensors from contamination and through Nafion tubing on the filter that removes moisture from the samples that would affect the measurements and the units calibration.

Laser technology
The oxygen concentration of the gas in the sample cell is measured using laser diode absorption technology. The laser diode in the oxygen sensor produces light at a wavelength (760 nanometers) that is absorbed by oxygen. The light passes through the gas pumped into the sample cell and onto the surface of a detector. The output of the sensor is inversely proportional to the concentration of oxygen in the sample because the amount of light reaching the detector decreases as the concentration of oxygen in the sample increases. The GA-200 has a very fast response time that enables breath to breath analysis of gas concentrations because the unit analyzes the gas sample every 10 milliseconds, or 100 times per second. During each measurement interval, the analyzer is zeroed automatically by electronic tuning of the laser to a wavelength not absorbed by oxygen.


Ready to use

The GA-200 gas analyzer is calibrated at the factory and is ready to take measurements. Just connect the source of the gas sample to the gas analyzer with the proper connections and press the RUN key - the results will appear on the built-in screen, as shown below.



THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Ambient Temperature 5-40oC Operation
-20-60oC Storage
Cell Pressure 10.2-17.4 PSI
500-900 mmHg
Warm-Up Time 5 minutes
Altitude Two point calibration required
for each 2,000 ft. change altitude
Humidity 0-95%, non-condensing
Range 5-100% O2 / 0-10% CO2
Resolution 0.1% in 0-100% range
0.01% in 0-10% range
Flow with Pump 50-250 ml/min, adjustable
Response Time 150ms@ 150ml/min flow
Stability (4 Hours) +0.3% O2 in XC Mode
+0.1% in LN Mode
Power Requirements of Analyzer 12VDC, 1.5A
Requirements of the External Power Supply 95-250VAC, 47-63 Hz
Dimensions 190 x 76 x 280mm (WxHxD)
Weight Analyzer: 2.3kg / Power Supply: 0.7kg