(Model: IX-404)
An economical, general purpose data acquisition and analysis module for use with any analog amplifier. With the Pressure-Volume Loop analysis, it's an ideal tool for cardiology, research on cardiomyopathy, Left ventricular hypertrophy, aortic and mitral stenosis, studies on End-systolic pressure volume relationship, and much more!

- More information - - Documents - - Contact Bioseb -
Technical specifications   Download PDF
This page is available in following languages:

Presentation

IX-404 is an economical, general purpose data acquisition and analysis module for use with any analog amplifier. The recorder offers 16-bit data collection at speeds up to 10 KHz, providing acquisition speeds appropriate for most research applications. The included PVLOOP software allows “one-click” control of the entire acquisition process, plus a large library of standard analytical functions to process data. The IX-404 recorder is powered via a USB interface to any Macintosh or PC, eliminating the need to install special interface cards. Users are typically recording and analyzing signals within minutes of installation.

Features

Resolution
The IX-404 recorder uses a 16-bit A/D converter to sample data over its full input range of ±10V at speeds up to 10kHz. The low noise (<1mV) greatly reduces the need for gain and offset. When used with a standard x10 oscilloscope probe, ranges of ±100V can be monitored.

Data Recorder with Pressure-Volume Loop Analysis by Iworx and Bioseb: Pressure-volume loop in the PVLOOP software
Pressure-volume loop in the PVLOOP software
PVLOOP Software
The PVLOOP Software (ref. IX-404-PLV) provides powerful analysis tools. Built-in PVLOOP acquisition and analysis software is easy and straightforward. It supports real units and a time based display that is not coupled to sample rate. The display can be configured to allow viewing of as many data points as the user desires. Scrolling, zoom-in and zoom-out tools, together with a searchable list of user interventions, make finding important areas of data easy.

PVLOOP software provides a powerful array of built-in data analysis tools. It strikes a balance between the straightforward, general operations that everyone uses and the vertical, complex routines that only you use. The result is a powerful analytical tool that can go to work on your data right away, or be customized to do very specific and complex analyses.

Exceptional Value
IX-404 provides turnkey continuous recording solutions at a fraction of the cost and complexity associated with systems requiring PCI bus plug-in cards. No breakout box is required, as connectors are part of the enclosure. In fact, no other hardware is required to get up and running.


System Requirements

IX-404 requires a minimum Pentium II or Celeron level 500MHz computer running at least Windows 98, with at least 128 megabytes of RAM, at least 10 megabytes of free space on the hard drive, and 1 free USB port. Internet connection is required for web updates.

Domains of application

• For use with a broad range of analog amplifiers
• Records and measurements data of force, blood pressure, and displacement, and much more
• Pressure-volume loop analysis in cardiology
• Cardiomyopathy, Left ventricular hypertrophy, aortic and mitral stenosis, and more
• Studies on End-systolic pressure volume relationship (ESPVR)
• All physiology applications in teaching or research context

Available with Pressure Volume Loop Analysis

IX-404 is available in two configurations, with (IWX/404-PVL) or without (IWX/404) a pressure volume loop analysis.

THE INFORMATION IN THIS WEB SITE AND IN LINKED PAGES AND DOCUMENTS IS PROVIDED "AS IS" AND DOES NOT CREATE ANY EXPRESS OR IMPLIED WARRANTY ABOUT BIOSEB OR ITS PRODUCTS OR SERVICES.

Information published on this Web Site as well as services, product specifications, availability and prices are subject to change without notice. BIOSEB may also make improvements and/or changes in the products and/or the programs described in this Web Site at any time without notice.

BIOSEB has made reasonable efforts to verify that the information in this Web site was accurate when first published. Such information may contain errors or omissions, however, and it is subject to change without notice. Bioseb does not undertake to update this information to include any such changes or to correct errors or omissions. Bioseb assumes no responsibility for any use of the information in this Web site or for any infringement of patents or other rights of third parties that may result. Certain information may be country-specific and may not apply in all countries.

Input
Digital Inputs 4
Input Impedance 1M Ohm
Input Range + 10 VDC
Noise <1 mV (1 part in 20K)
Digital Output
Lines 4
Digital Output Connector BNC
A/D Converter
Sample Speed (samples/second) 10,000 simultaneously
Resolution 16 Bit
Interface USB 1.1 / 2.0 full speed
General
Enclosure Plastic (CE Compliant)
Power USB
Software
Software iWorx PVLOOP
Trigger Modes External Trigger (TTL or Contact Closure), Threshold Trigger from Data, User Trigger
Display Real time, user definable Screen Time independent of Sample Rate, User Definable Units, AutoScale, Full Scale or User Defined Scale

Model:
IX-404
Data Recorder with Pressure-Volume Loop Analysis
Contact us
Print version

Bioseb - In Vivo Research Instruments
Phone worldwide : +33 442 344 360 - USA/Canada : (727) 521-1808
e-Mail : Worldwide: info@bioseb.com - USA/Canada: info-us@bioseb.com