Effects of transdermal lidocaine or lidocaine with prilocaine or tetracaine on mechanical superficial sensation and nociceptive thermal thresholds in horses-

Authors
FJ Söbbeler, SBR Kästne


Lab
Clinic for Small Animals, University of Veterinary Medicine Hannover, Germany

Journal
Veterinary Anaesthesia and Analgesia

Abstract
Objective:To evaluate the transdermal local anaesthetic effect of lidocaine or lidocaine combined with prilocaine or tetracaine in horses.
Animals:A total of five healthy adult warmblood horses.
Methods:Horses were clipped bilaterally at the withers, cranial saddle area and caudal saddle area. Baseline measurements for mechanical superficial sensation via von Frey filaments and nociceptive thermal thresholds were performed. A 5% lidocaine patch (12 hour exposure, treatment L), a lidocaine/prilocaine cream (each 2.5%, treatment LP) and a lidocaine/tetracaine cream (each 7%, treatment LT) were applied (both 2 hour exposure). The same product was applied at the same location bilaterally, but on the right side an epidermal micro-perforation (dermaroller, 1200 needles) was performed prior to application. A total of five more measurements were performed at each location, immediately at the end of exposure time followed by hourly measurements. Thermal thresholds normalized to thermal excursion were analysed. One- or two-way anova and the Wilcoxon signed-rank test were used for statistical analysis with p < 0.05 considered significant.
Results:Epidermal micro-perforation had no enhancing effect. Treatments L, LP, and LT resulted in increased thermal excursion (%) immediately (84.7 ± 12.9; 100.0 ± 0.0; 100.0 ± 0.0) and 1 hour (81.7 ± 66; 86.0 ± 17.7; 87.7 ± 14.4) after the removal of the respective product compared to baseline (66.1 ± 9.3; 69.9 ± 8.3; 76.5 ± 7.8). Superficial mechanical sensation was decreased by the lidocaine-and-tetracaine cream at all time points, and by the lidocaine patch and lidocaine-and-prilocaine cream for three measurements.
Conclusions and clinical relevance:Eutectic mixtures of lidocaine with either prilocaine or tetracaine led to a reduction in thermal nociception and mechanical sensation for up to 2 hours.

BIOSEB Instruments Used:
Von Frey Filaments (Bio-VF-M)

Produits associés

Publication request

Merci de votre intérêt pour notre gamme de produits et de votre demande pour cette publication qui vous sera envoyée si l'équipe de recherche et la revue le permettent. Notre équipe commerciale vous contactera dans les plus brefs délais.