Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative...
Array
(
[id_prestablog_news] => 1252
[id_shop] => 1
[date] => 2020-03-24 00:00:00
[date_modification] => 2024-02-09 14:15:12
[langues] => ["1","2"]
[actif] => 1
[slide] => 0
[url_redirect] =>
[average_rating] =>
[number_rating] =>
[author_id] => 1
[featured] => 0
[prim_key] => 2462
[id_lang] => 2
[title] => Total Knee Arthroplasty with a Ti6Al4V and PEEK Prosthesis on an Osteoarthritis
[paragraph] => Total Knee Arthroplasty with a Ti6Al4V/PEEK Prosthesis on an Osteoarthritis Rat Model: Behavioral and Neurophysiological Analysis
[content] => Authors
L Mathieu, L Jean-Marc, J Chaves-Jacob, T Coyle et al
Lab
Aix-Marseille UniversitŽ, CNRS, Institut des Sciences du Mouvement, Marseille, France.
Journal
Scientific Reports
Abstract
Arthroplasty is a surgical procedure to restore the function of the joint of patient suffering from knee osteoarthritis. However, postoperative functional deficits are reported even after a rehabilitation program. In order to determine the origin of functional deficits of patient suffering from knee osteoarthritis and total knee arthroplasty, we developed a rodent model including a chemically-induced-osteoarthritis and designed a knee prosthesis (Ti6Al4V/PEEK) biomechanically and anatomically adapted to rat knee joint. Dynamic Weight-Bearing, gait kinematics, H-reflex from vastus medialis muscle and activities from metabosensitive III and IV afferent fibers in femoral nerve were assessed at 1 and 3 months post-surgery. Results indicate that knee osteoarthritis altered considerably the responses of afferent fibers to their known activators (i.e., lactic acid and potassium chloride) and consequently their ability to modulate the spinal sensorimotor loop, although, paradoxically, motor deficits seemed relatively light. On the contrary, results indicate that, after the total knee arthroplasty, the afferent responses and the sensorimotor function were slightly altered but that motor deficits were more severe. We conclude that neural changes attested by the recovery of the metabosensitive afferent activity and the sensorimotor loop were induced when a total knee replacement was performed and that these changes may disrupt or delay the locomotor recovery.
BIOSEB Instruments Used
Dynamic Weight Bearing 2.0 (BIO-DWB-DUAL)
[meta_description] =>
[meta_keywords] => https://search.proquest.com/openview/c3901f2ffbc6bbb8cea8bf10650fa7a1/1?pq-origsite=gscholar&cbl=2041939
[meta_title] =>
[link_rewrite] => total-knee-arthroplasty-with-a-ti6al4v-and-peek-prosthesis-on-an-osteoarthritis-rat-model--behavioral-and-neurophysiological-analysis
[actif_langue] => 1
[read] => 1130
[count_comments] => 0
[id] => 1252
[categories] => Array
(
[70] => Array
(
[id_prestablog_categorie] => 70
[title] => Arthrite & Arthrose
[link_rewrite] => Arthrite-Arthrose
)
[21] => Array
(
[id_prestablog_categorie] => 21
[title] => Articulations
[link_rewrite] => Articulations
)
[2] => Array
(
[id_prestablog_categorie] => 2
[title] => Publications
[link_rewrite] => publications
)
)
[authors] =>
[paragraph_crop] => Total Knee Arthroplasty with a Ti6Al4V/PEEK Prosthesis on an Osteoarthritis Rat Model: [...]
[link_for_unique] => 1
[products_liaison] => Array
(
[1216] => Array
(
[name] => Distribution Pondérale Dynamique 2.0
[description_short] => Un système permettant l'analyse de la posture des animaux par la répartition du poids sur chacune des 4 pattes. Le DWB est un test unique dans l'étude de nombreux modèles de douleurs, principalement non évoquée , neuropathique ou encore inflammatoire ainsi que pour les études sur l'osthéoarthrite et divers affections du SNC.
Le nouvelle version DWB2 intègre une nouvelle interface logiciel plus simple avec gestion des listes d'animaux ainsi que de nouveaux algorithmes d'analyse automatique de la posture.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-spontanee-deficit-de-posture/1216-dynamic-weight-bearing-20.html
)
[1877] => Array
(
[name] => Dynamic Weight Bearing 2.0 – Module Postural Additionnel
[description_short] => Étendez votre analyse grâce à des calculs posturaux et locomoteurs avancés
Le système de Distribution Pondérale Dynamique (DWB2) de BIOSEB s’enrichit avec l'ajout du Module Postural. Ce complément logiciel optionnel améliore l’analyse standard de la répartition du poids en intégrant des nouveaux calculs conçus pour l’étude de la posture, de la locomotion et de l’activité des animaux.
Développé en collaboration avec le laboratoire du Dr. Tighilet de l’Université Aix-Marseille - CNRS, le Module Postural améliore votre DWB2 en fournissant des paramètres précieux pour les recherches sur la douleur, les troubles vestibulaires et les maladies neurodégénératives.


[thumb] =>
[img_empty] => /var/www/vhosts/de3310.ispfr.net/bioseb2024/modules/prestablog/views/img/product_link_white.jpg
[image_presente] => 1
[link] => https://bioseb.com/fr/douleur-spontanee-deficit-de-posture/1877-dynamic-weight-bearing-20-module-postural-additionnel.html
)
)
)
1 En lire plus